911SentinelCall

Seattle construction fence rules.

How tall the fence goes, when you need a covered walkway, how gates and lights work, and what the building code adds after hours.

What are the construction fence requirements in Seattle?

Seattle sets construction fences through its Street Use rules (SMC Title 15 and SDOT Director's Rule 10-2015), not the building code. Where a fence is required it must be at least seven feet high and continuous along the construction side, with gates that swing inward and stay fastened shut when not in use. The sidewalk stays open and lit from sunset to sunrise.

The fence keeps people out by day. We watch it at night

A seven-foot fence slows people down; it doesn't tell anyone when someone climbs it. 911 Sentinel puts cameras on the gate, the fence line and the materials, watched live by AI and our team. The alert reaches our team immediately, an operator warns the person off right away with a recorded voice, siren and spotlights, then calls your superintendent, and police if no one answers in the time you set. Construction site security in Seattle starts at $900 a month with the camera included; see construction site security and what it costs.

Which rules govern construction fences in Seattle?

Seattle took the pedestrian protection table out of its building code. Section 3306.1 of the 2021 Seattle Building Code now says protection of the public, sidewalks and streets during construction is provided as the Street Use Ordinance, SMC Title 15, requires. SDOT spells that out in Director's Rule 10-2015, in force since January 1, 2016, and walks applicants through it in Client Assistance Memo 2110.

The starting rule is that the sidewalk next to a work site stays open. Closing it is a last resort under SMC 15.22.024, granted only when the permittee shows the existing walkway isn't practical. A Street Use application shows how pedestrians get past the site during work and non-work hours.

When does a Seattle site need a fence or covered walkway?

SMC 15.22.120 sets the minimum by how tall the construction is and how close it sits to the public place:

Minimum pedestrian protection by height and distance (SMC 15.22.120, as set out in SDOT DR 10-2015)
Construction heightDistance from the public placeMinimum protection
8 feet or lessLess than 6 feetOpen walkway with a railing at least 3.5 feet high
8 feet or less6 feet or moreOpen walkway with a 3.5-foot barricade and four or more amber warning lights
More than 8 feetLess than one quarter of the construction heightFence and covered walkway
More than 8 feetMore than one quarter of the construction heightOpen walkway and fence
ExcavationWithin 4 feet of the street marginOpen walkway and railing

Railings and barricades must withstand 50 pounds per lineal foot applied horizontally to the top rail.

How tall does a construction fence have to be in Seattle?

Minimum construction fence height
7 ft
Minimum clear ceiling inside a covered walkway
8 ft
Minimum clear walkway width; 8 ft in busy business districts
4 ft
  • At least seven feet high, unless the permit sets otherwise.
  • Continuous along the construction side, broken only by gates.
  • Solid and tight where debris or dust could reach the walkway, with screened view holes.
  • Wire mesh from four to seven feet within 30 feet of an intersection, for sight lines.
  • Footings marked and kept out of the four-foot walkway.
  • Gates swing inward, away from pedestrians, toward the work site.
  • Gates stay securely fastened shut whenever they aren't in use.

What does a covered walkway need?

CAM 2110 adds one line that matters after dark: where visibility into a covered walkway is limited by where it sits or what's around it, security monitoring may be required.

  • A clear ceiling at least eight feet high, tightly boarded so water can't fall through.
  • A roof designed for at least 150 pounds per square foot.
  • A continuous handrail at least 3.5 feet high on at least one side.
  • Jersey or water-filled barriers on the side facing traffic.
  • Lighting inside, continuous from sunset to sunrise.
  • Washable walls, roof and floor kept free of postings and graffiti.

What the building code adds after hours

The Street Use rules handle the public side of the fence. Chapter 33 of the Seattle Building Code covers the site itself. A fire watch is required during nonworking hours for construction more than 40 feet above the lowest adjacent grade, and for new multistory construction over 50,000 square feet per story (Section 3314.1.1). After a demolition, the site is left level, holes are filled or protected with secure fences, and a lot left vacant for more than six months is seeded (Section 3303.4).

Nights and weekends are when sites lose copper, tools and equipment. Plan for them with the construction site security checklist, the holiday shutdown checklist and how to stop copper wire theft.

Common questions

How high does a construction fence need to be in Seattle?

Where Seattle's Street Use rules require a fence, it must be at least seven feet high and continuous along the construction side. Within 30 feet of an intersection, the part from four to seven feet high must be wire mesh so drivers and pedestrians can see each other.

Do I need a permit for a construction fence on the sidewalk in Seattle?

Work that uses the sidewalk or street needs an SDOT Street Use permit. The application includes site and traffic control plans showing how pedestrians get past the site during work and non-work hours, and a covered walkway needs its own drawings.

When is a covered walkway required in Seattle?

Under SMC 15.22.120, construction more than eight feet high that sits closer to the public place than one quarter of its height needs a fence and a covered walkway. Farther back, an open walkway and a fence are the minimum.

Can a construction site close the sidewalk in Seattle?

Only as a last resort. Seattle requires the sidewalk next to a work site to stay open unless the permittee shows the existing walkway isn't practical. SDOT then considers a reroute into the street or a detour across it, and it can require a sign at the closure with the permit number, how long it lasts and a contact.

When does a Seattle construction site need a fire watch?

The Seattle Building Code requires a fire watch during nonworking hours for construction more than 40 feet above the lowest adjacent grade, and for new multistory construction with more than 50,000 square feet per story, or wherever the fire code official or the site safety plan requires it.